Validation Lab

Registered methods, paired evidence and reproducible measurement reports.

Local validation recordsStored on this device. Exported studies require their own consent, retention and access controls.Institutional trial workspace

Registered studies

0

Observed-data plans

0

Supported movement plans

5

One scoped task per study

Shipped human accuracy datasets

0

Independent reference data required

01

Squat

sagittal · max endpoint

Reference recordings required

02

Countermovement jump

sagittal · max endpoint

Reference recordings required

03

Gait

sagittal · rom endpoint

Reference recordings required

04

Lunge

sagittal · max endpoint

Reference recordings required

05

Single-leg stance

frontal · rom endpoint

Reference recordings required

Registered studyEvidenceTask / variableRegisteredRevision

No validation studies yet. Register an observed-data plan or inspect the labelled software fixture.

Restore an encrypted study backup

Restores raw evidence and the locked plan without replacing an existing study. Results must be recalculated. Earlier local registration dates are not independently verified.

Product claims and evidence boundaries

No human accuracy dataset or validated commercial claim is bundled with this release. A study result provides scoped evidence for independent assessment.

CapabilityOutput classInterpretation boundaryEvidence required
Raw image landmarksModel-estimatedNormalized image coordinates and model visibility; visibility is not an accuracy interval.Paired observations across the specified devices, tasks, population and occlusions.
Projected 2D anglesDerived estimateFourteen defined plane-specific variables. No automatic anatomical 3D interpretation.Independent same-plane reference using the identical angle definition, synchronization and recording inventory.
Event timestampsManual or imported detector outputContact, takeoff and repetition events are not automatically validated detections.Independent event definitions and one-to-one event precision, recall and timing comparisons.
RepeatabilityStudy-specific statisticICC(A,1), occasion shift and within-subject error describe the supplied repeated endpoints.Stable test construct, two fixed occasions, complete participant rows and independent analysis review.
Scaled pelvis excursionProjected calibrated estimatePelvis midpoint displacement is not whole-body center of mass or jump height.Separate position validation with same-plane calibrated reference. Not evaluated by this angle-study module.
Force, torque, power and EMGUnavailable from this camera pipelineNo force, inverse-dynamics or activation inference is supplied by this validation lab.Appropriate sensors, validated models and a separate kinetics validation program.
Injury risk or diagnosisNo claim supportedSoftware quality and angle agreement do not establish a clinical outcome model.A separate intended-use-specific clinical validation and approval process.
Synthetic fixtures and teaching modelsModelledKnown numerical data test software behavior, never human measurement accuracy.Deterministic engineering tests only.